Arteriocyte Medical Systems Focused on Improving Surgical Outcomes 
Corporate Homepage

MAGELLAN™ System Features and Benefits

One source, tamper-proof packaging contains everything required to perform component separation as well as patient phlebotomy.

Each procedure requires the use of one Arteriocyte Medical Systems Magellan™ Platelet Separator Disposable Kit, which includes components necessary for a single patient platelet separation procedure. The separation chamber and associated tubing can be used with the same patient for up to three complete separation cycles.

The Arteriocyte Medical Systems Magellan™ Platelet Separator Disposable Kit includes the components listed below. If more than one separation cycle will be performed with the same patient, additional 10-ml and 60-ml B-D™* syringes can be purchased from Arteriocyte Medical Systems.

  • 30-ml vial of ACD-A anticoagulant
  • 60-ml syringe
  • 1-ml syringe
  • 5- ml syringe
  • IV Site Prep Kit
  • Separation chamber with attached tubing
  • 18-gauge x 3.8 cm (1.5”) needle
  • 17-gauge needle and IV tubing

A Magellan™ Dispenser Tip is required for the use of this dispenser kit. Dispenser kits are available from Arteriocyte Medical Systems and include the following components:

  • Procedure tray
  • Two 30-mlsample cups
  • 12-ml Syringe
  • 1-ml Syringe
  • Dispenser handle
  • Dual syringe plunger clip

System Specifications

Note: Technical data, features and options referenced here are based on the latest information available at the time of printing. Arteriocyte Medical Systems reserves the right to change specifications without notice.

Electrical

  • Classification: Class 1, Type B Equipment, Ordinary Continuous Operation

Power

  • Voltage: 100 – 240 V-
  • Frequency: 50- 60 HZ
  • Phase: Single
  • Current: 1.3 amps
  • Fuses: 5 x 20 mm / 6.3 amps
  • Power cord: 2 wires plus ground (earth) connector 3- prong hospital grade

Speed and Flow Rate Specifications

  • Centrifuge: 0 – 4,000 rpm (± 5 %)
  • Syringe Pump: 0 – 60 ml/min (± 5 %)
  • Separation Chamber Maximum Fluid Volume: 60 ml
  • Separation Chamber Maximum Fluid Density: 1.1 kg/dm3

Dimensions

  • Width: 18 inches (47 cm)
  • Height: 13 inches (32 cm)
  • Depth: 17 inches (44 cm)
  • Weight: 24 lb. (11 kg)

Temperature Limit

  • Operational: 10°C - 30°C (50°F - 86°F)
  • Storage: -40°C - 66°C (-40°F - 150°F)

Humidity Range

  • Operational: 10 – 95% non-condensing
  • Storage: 10 - 95% non-condensing

RS-232 Port

  • This port is to be used only by authorized service personnel.

 


  Arteriocyte Medical Systems

  Locations:
 
  Ohio Offices
  11000 Cedar Avenue, Suite 270
  Cleveland, Ohio 44106, USA
  Phone: 216-658-3970
 
  Massachusetts Offices
  45 South Street
  Hopkinton, MA 01748, USA
  Phone: 508-497-8950

  E-mail: info@arteriocyte.com
  Phone: 1-866-660-AMSI(2674)
  Fax: (216) 721-1215